CHARTERED QUANTITY SURVEYORS · CONTRACTS · CHANGE · CLAIMS

Commercial confidence, from contract to completion.

For data centre power teams.

Whatever your trade, we make sure the contract you signed pays you for all the work you deliver. Contract reviews, change control, notices and claims from a team that has delivered commercial management on data centre projects, on both sides of the table: for main contractors and for subcontractors.

Chartered Quantity Surveyors · RICS-regulated firm · NDA on request · UK & Europe

Data centre power trainGrid connection feeds a transformer, switchgear, UPS and rows of racks, with cooling units on the roof. Select a component to open its trade.Grid connectionGRIDTransformerTXSwitchgearSWGRUPSUPSRacksRACKSCooling unitsGRID CONNECTION → TRANSFORMER → SWITCHGEAR → UPS → RACKSSelect a component to find your trade
CONTRACT FORMS
NEC4 ECC ·NEC4 Subcontract ·JCT ·FIDIC 2017 ·VOB/B ·UAV-GC ·Hyperscaler flow-down terms ·Purchase orders ·
0 weeks

to notify a compensation event under NEC4 ECC, or lose the time and money. Seven weeks under the NEC4 subcontract.

0 days

to give a Notice of Claim under FIDIC 2017, with the fully detailed claim due by day 84.

§2(6)

VOB/B. Extra work in Germany must be announced before you carry it out if you want to be paid for it.

Day 0

the day the instruction lands on site. The clock starts long before the invoice does.

01 / FIND YOUR TRADE

If you work on data centres without your own commercial team, this is for you.

Most subcontractors and suppliers on a data centre are specialists first. Your teams are excellent at building, making and commissioning. They weren't hired to manage NEC, FIDIC or a hyperscaler's bespoke terms. Pick your trade to see where margin usually leaks, and what we do about it.

TRD-01

Electrical installation

MV/LV distribution, cabling, containment, small power and lighting.

WHERE MARGIN USUALLY LEAKS

  • Programme compression and out-of-sequence working, with no evidence of lost productivity.
  • Late changes to rack layouts and power densities, instructed on site.
  • Daywork sheets that are never signed and never paid.

WHAT WE DO FOR YOU

A live change register, signed daywork, and disruption records that turn lost hours into recoverable cost.

Book a health check for my contract →

TRD-01

Electrical installation

MV/LV distribution, cabling, containment, small power and lighting.

WHERE MARGIN USUALLY LEAKS

  • Programme compression and out-of-sequence working, with no evidence of lost productivity.
  • Late changes to rack layouts and power densities, instructed on site.
  • Daywork sheets that are never signed and never paid.

WHAT WE DO FOR YOU

A live change register, signed daywork, and disruption records that turn lost hours into recoverable cost.

Book a health check for my contract →

02 / NOTICE CLOCK

How long have you got?

Pick your contract and the day you became aware of the event. We'll show you the standard notice deadline and how many days are left.

Contract form

Standard period: 56 calendar days from the date you became aware.

0days remaining

Standard notice deadline:
Tuesday 12 January 2027

Standard unamended wording only. Many data centre contracts shorten these periods in their amendments, and some events are exempt from the time bar. This is a guide, not legal advice.

03 / THE PROBLEM

Built to manufacture. Contracted like a main contractor.

Data centre programmes are fast and the contracts are heavy. Risk flows down the chain until it lands with the firm least equipped to manage it. In our experience, margin is rarely lost on the engineering. It's lost in the paperwork.

FLOW-DOWN

Terms you never negotiated

Hyperscaler and developer terms pass down the chain, often unchanged, to suppliers who never saw the main contract.

TIME BARS

Deadlines that kill claims

Miss a notice by a day and you can lose the money, however strong your case.

SITE CHANGE

Verbal instructions

Change is agreed on site, in meetings and over WhatsApp, and never formally instructed or notified.

PROGRAMME

Delay that lands on you

The site isn't ready, the building isn't ready, the power isn't on. Your factory slot, storage and re-delivery costs still have to be paid.

CASHFLOW

Applications cut back

Valuations reduced, retention held and milestones tied to commissioning outside your control.

CAPACITY

Engineers doing QS work

Your project managers are also writing notices and pricing variations, on top of delivering the package.

WATCH · 60 SECONDS

One of the fastest-growing sectors in construction. Don't get left behind commercially.

Fast-track programmes, long supply chains and bespoke contracts put your margin at risk. One minute on how we protect it.

04 / WHAT WE DO

One commercial partner across the whole life of the package.

Use one service or all six. Every engagement has an agreed scope and fee before we begin.

BEFORE YOU SIGNTENDERDELIVERYDISPUTE AVOIDANCECLOSE-OUT
M-01BEFORE YOU SIGN

Contract & order review

We read the order, the subcontract and the main contract terms that flow down, then flag the risk and propose amendments you can negotiate.

OUTPUT → risk crib sheet · notice calendar · mark-up

M-02TENDER

Bid commercial review

We check qualifications, exclusions, payment terms and LD exposure before you price, so the margin you bid is the margin you keep.

OUTPUT → qualifications schedule · risk register

M-03DELIVERY

Change & variation control

Instructions captured, notified and priced on time, whether they're NEC compensation events, JCT variations or VOB/B Nachträge.

OUTPUT → change register · notices · quotations

M-04DELIVERY

Valuations, applications & cashflow

Monthly valuations, payment applications, payment and pay less notice tracking, retention and CVR reporting your board can trust.

OUTPUT → applications · cashflow forecast · CVR

M-05DISPUTE AVOIDANCE

Delay & claims support

Extension of time and loss and expense narratives built from programme analysis and contemporary records. Written to be agreed, not argued.

OUTPUT → claim submission · evidence pack

M-06CLOSE-OUT

Final account

We close the account: reconciled scope, agreed variations, released retention, and negotiation support until it's signed.

OUTPUT → agreed final account

05 / CONTRACT ATLAS

Different country, different rulebook. Same deadlines.

Data centre suppliers work across borders, and so do their contracts. Select a form to see where the commercial traps usually sit.

UK · INFRASTRUCTURE & MAJOR PROJECTS

NEC4 ECC / ECS

THE CLOCK

Notify a compensation event within 8 weeks of becoming aware of it, or the prices and Completion Date don't change. Under the NEC4 subcontract it's 7 weeks.

WHERE SUPPLIERS GET CAUGHT

Instructions given in meetings or by email that nobody notifies. Quotations that miss their deadline and get assessed by the other side. Programmes that are never accepted.

WHAT WE DO

We set up a compensation event and early warning register from day one, write the notifications and quotations, and keep your programme accepted.

A short summary to help you spot risk. It isn't legal advice, and every contract is amended differently. We're Chartered Quantity Surveyors, not lawyers. Where you need local-law advice, we'll work alongside a qualified lawyer in that jurisdiction.

06 / SIGNALS

Sound familiar?

If two or more of these apply, a contract health check will pay for itself.

Commercial warning signs

07 / HOW IT WORKS

From inbox to crib sheet.

  1. 01

    Share the contract

    Send the order or subcontract, under NDA if you prefer. We run a conflict check before we read it in detail.

  2. 02

    Agreed scope

    You get a short proposal with the scope, the fee and the turnaround. Nothing starts until you approve it.

  3. 03

    Crib sheet & calendar

    We deliver your risk crib sheet, notice calendar and recommended amendments, then walk your team through them.

  4. 04

    Support as you need it

    Stop there, or keep us on the package for change, applications and close-out.

08 / WAYS TO WORK TOGETHER

Start small. Scale with the programme.

PER PROJECT

Package support

Change control, applications, notices and claims for one live package. Remote, with site visits when they add value.

Talk to us

MONTHLY RETAINER

Commercial Partner

A part-time commercial lead embedded in your business across all your data centre work, without a permanent hire.

Talk to us

09 / WHO YOU'LL WORK WITH

A team that has sat on both sides of the table.

Our team has delivered commercial management on data centre power and infrastructure projects, as well as major UK infrastructure, for main contractors and for subcontractors. We know how packages are bought, how change is instructed on a live site, and how final accounts are won or lost. We bring that experience to suppliers and specialist subcontractors who don't have their own commercial team.

  • Chartered Quantity Surveyors (MRICS)
  • MCIOB
  • RICS-regulated firm 894570
  • NDA on request
  • NEC
  • JCT
  • FIDIC
MSurveying Data Centre Commercial
Regulated by RICS

10 / QUESTIONS

Straight answers.

No. We're Chartered Quantity Surveyors: commercial and contract specialists. We tell you what the contract means in practice and how to protect your entitlement. Where you need formal legal advice, especially outside the UK, we work alongside qualified lawyers.

CONTRACT HEALTH CHECK

Send us one subcontract or order. We'll show you where the money is at risk.

NDA first if you need one. Conflict check before we read anything. Scope and fee agreed up front.

Regulated by RICS · Firm no. 894570 · Chartered Quantity Surveyors · Professional indemnity insured · Mytoor Ltd, company no. 11034271